Testing CB Antenna for High SWR Readings

Do you have a volt/ohm meter? If so, then you can proceed with Testing CB Antenna to verify that it has no issues, below is how to do so.

Step 1: Testing the Antenna Coil

  • Remove antenna coil from the mount.
  • Touch one lead (negative or positive) of meter or tester to the center pin at the bottom of the antenna coil.
  • Touch the other lead of meter to either the threads on the bottom of the coil, or the chrome mast at top of antenna.
  • In either position, if the meter shows a shorted condition (needle swings to the far right), or reads continuity, the coil is in proper working order.

Step 2: Testing the Antenna Coax Cable

Source: CB-World

  • With the antenna coil removed, touch one lead of meter or tester to the center pin of the PL-259 connector.
  • Touch the other lead to the center hole located on the top of the SO-239 mount.
  • If this shows a shorted condition (or reads continuity), the center portion of the coax is in proper working order.
  • Touch one lead of meter to outer shell of the PL-259 connector.
  • Touch other lead of meter to the threads on SO-239 mount.
  • If this shows a shorted condition (or reads continuity), the shield portion of the coax is in proper working order.
  • Touch one lead (negative or positive) of meter or tester to the center pin of the PL-259 coax connector.
  • Touch the other lead of meter to either the threads on the SO-239 mount or the outer shell of the PL-259 connector.
  • If this shows no reading (or reads no continuity), the coax is not shorted out and is in proper working order.

Step 3: Testing CB Antenna Coax Connector

  • With the antenna coil removed, touch one lead of meter or tester to the center pin of the PL-259 coax connector.
  • Touch the other lead of meter to threads on the SO-239 mount or the outer shell of the coax cable.
  • This connection should show no reading or continuity. While these two points are connected through the meter, wiggle the connector and observe the meter or continuity tester.
  • If there is no change in indication, the connector portion of the antenna is in proper working order. If the needle swings to the right, the connector is bad and should be replaced.

The post Testing CB Antenna for High SWR Readings appeared first on CB Antenna - Strykerradios.



This post first appeared on Dual CB Antenna Installation For Truckers, please read the originial post: here

Share the post

Testing CB Antenna for High SWR Readings

×

Subscribe to Dual Cb Antenna Installation For Truckers

Get updates delivered right to your inbox!

Thank you for your subscription

×