Get Even More Visitors To Your Blog, Upgrade To A Business Listing >>

Flow Through Spa Heaters


Flow through heaters are tube style heaters with an internal heating element.
These tubes range in length from 8" - 19", the most common length of spa heater is 15". 

Heater tubes are also listed by diameter; 1.5", 2" or  2.5" which refers to rough ID of the heater tube nothing else. Split nuts must follow these guidelines.
As most spa builders do not make their own heaters, they are manufactured by Thermproducts which was formally known as (RMF Related Metal, Aquatemp, Thermocore). This makes replacements easy to find & readily available. If you do not succeed in matching a part number for your heater just let us know & we'd be happy to help.

 
Regularly stocked heaters will have a 'Click Here' that takes you to that heater on www.spapartsshop.com Heaters which aren't too common will have  [Special Order Heater] that just means we'll need to order one in for you. Special orders usually take 7-10 days. Contact us for ordering details.


Some heaters have the elements welded in, these heaters cannot have the element replaced on its own. But if you want to save your self some money Spa Parts Shop also carries an extensive selection of replacement heater elements.

Unless otherwise listed Pressure Switches, Thermostats & Hi limits are not included with the heater tubes. It would be wise to replace the pressure switch when replacing the heater.
C2550-F002 [Special Order Heater]
5.5kw 240v 2″ x 19″ Flow Thru Heater
Replaces F2550-0002
C2400-1008ET [Special Order Heater]
VITA 4.0kw 240V 2″x17.5″ Flow Thru Heater
C2400-0119 [Special Order Heater]
SUNDANCE/MARQUIS 4.0kw 240V 2″x15″ L Shape Heater
C2400-0736 [Special Order Heater]
LA – ADVANCED 4.0kw 240V 2″x15″ Flow Thru Heater
Replaces: 48-3400-10-736H
C2400-0309 [Special Order Heater]
Replaces: 20-00278-C
C2550-2300 Click Here to View
CORRECT TECH 5.5kw 240V 2″x12.5″ Flow Thru Heater
Replaces: C2550-2300ET
C2400-0503-TPS Click Here to View
4kw 240v 2″ x 15″ Dual sensor heater for Free Flow systems
Replaces: 58001
C2400-0807-F [Special Order Heater]
4kw 240v 2″ x 15″ Dual sensor heater for Free Flow systems
Replaces: 58085
C2550-0304A Click Here to View
BRETT EM100 & EM190 / ACURA / ACC / ACTION / SPLASH / PDC / HYDRO QUIP 5.5kw 240V 2″x15″ Flow Thru Heater
Replaces: C2550-0304TI, (-1 or PD or ET-PD), C2550-0314 (ET or EP), 20-00430, 20-00417, 20-00307, B24055E, B24055E, 48-3300-10-304H
C2400-0304 [Special Order Heater]
BRETT EM100 & EM190 / ACURA / ACC / ACTION / SPLASH / PDC / HYDRO QUIP 4.0kw 240V 2″x15″ Flow Thru Heater
Replaces: C2400-0304TI, (-1 or PD or ET-PD), C2400-0314 (ET or EP), 20-00433, 20-00434 (4.5kw), 20-00454, 20-00317, B24040E
C2550-1056 Click Here To View
ACURA 5.5kw 240V 2″x15″ Flow Thru Heater
Replaces: C2550-1056TI, B24055A
C2550-1054 [Special Order Heater]
ACURA / ACC 5.5kw 240V 2″x15″ Flow Thru Heater
Replaces: C2550-1054TI, C2550-1054TI-1
C2400-1054 [Special Order Heater]
ACURA / ACC 4.0kw 240V 2″x15″ Flow Thru Heater
Replaces: C2400-1054TI, C2400-1054TI-1
C2550-1004 Click Here To View
ACC 5.5kw 240V 2″x12″ Flow Thru Heater
Replaces: C2550-1004TI, C2550-1004TI-1
C2400-1004 [Special Order Heater]
ACC 4.0kw 240V 2″x12″ Flow Thru Heater
Replaces: C2400-1004TI(-1), C2450-1004, B24040KX
C1100-0210-1 [Special Order Heater]
BALBOA 1.0kw 120V 1.5″x8.5″ Flow Thru Heater Used on Sundance
C2100-0210-1 [Special Order Heater]
BALBOA 1.0kw 240V 1.5″x8.5″ Flow Thru Heater Used on Sundance
C2550-0535 [Special Order Heater]
BALBOA 1st GEN 5.5kw 240V 2″x15″ Flow Thru Heater
Replaces: 48-3300-10-535H / C2550-0735 / C2550-0537 / C2550-07352 / 48-3300-10-435H / C2550-0435
C2400-0535 Click Here to View
BALBOA 1st GEN 4.0kw 240V 2″x15″ Flow Thru Heater
Replaces: C2400-C2839-2, C2400-0537, C2400-0735, C2400-07352, C2400-0435, 50081, 50067, B240040LB (Light Leader)
C2550-0809 Click Here to View
BALBOA LE 5.5kw 240V 2″x15″ Flow Thru Heater
Replaces: 58027
C2400-0809 [Special Order Heater]
BALBOA LE 4.0kw 240V 2″x15″ Flow Thru Heater
Replaces: 58029
C2550-0807 Click Here to View
BALBOA DUAL SENSOR TAPS 5.5kw 240V 2″x15″ Flow Thru Heater
Replaces: 58002, 58016
C2400-0807 Click Here for Details
BALBOA DUAL SENSOR TAPS 4.0kw 240V 2″x15″ Flow Thru Heater
Replaces: 58103, 58032
C2550-0033 [Special Order Heater]
BRETT / CALDERA 5.5kw 240V 2″x15″ Flow Thru Heater
Replaces: 48-3300-10-033HB
E21100-3100 Click Here To View
BRETT – PINNACLE HURICANE 11kw 240V 3″x15″ Flow Thru Heater Single Element
E21100-3150 [Special Order Heater]
BRETT – PINNACLE HURICANE 11kw 240V 3″x15″ Flow Thru Heater Dual Element
C2550-0066ET-A [Special Order Heater]
BRETT / GATSBY 5.5kw 240V 2″x15″ Flow Thru Heater
Replaces: 20-00319, 22-5020
B21100-2012 [Special Order Heater]
BRETT – PINNACLE 11kw 240V 2″x14″ EM1000 Flow Thru Heater Dual Element
20-00517 [Special Order Heater]
COATES 5.5kw 240V 2″x15″ Flow Thru Heater
Replaces: C2550-0517
20-00518 [Special Order Heater]
COATES 4.0kw 240V 2″x15″ Flow Thru Heater
C1100-0216 Click Here For Details
COLEMAN 1.0kw 120V 1.5″x10″ Flow Thru Heater
Replaces: 20-00450
C2500-2311 [Special Order Heater]
CORRECT TECH / INGENIOUS PROD 5.5kw 240V 2″x11″ Flow Thru Heater
Replaces: C2550-2311ET, 20-00635, B24055Y
C2400-2311 Click for Details
CORRECT TECH / INGENIOUS PROD 4.0kw 240V 2″x11″ Flow Thru Heater
Replaces: C2400-2311ET, 20-00634, B24040Y
C2500-2315 [Special Order Heater]
CORRECT TECH 5.5kw 240V 2″x14.5″ Flow Thru Heater
Replaces: C2550-2315ET, 20-00486
C2400-2315ET [Special Order Heater]
CORRECT TECH 4.0kw 240V 2″x14.5″ Flow Thru Heater
Replaces: C2400-2315ET, 20-00484
C2400-2300ET Click for Details
CORRECT TECH 4.0kw 240V 2″x12.5″ Flow Thru Heater
C2600-C1774-1 [Special Order Heater]
EMERALD / CONWAY 6.0kw 240V 1.5″x16″ Flow Thru Heater
C2550-3600ET-G [Special Order Heater]
GECKO 5.0kw 240V 3″x15″ Dual Element Flow Thru Heater
C2450-3101ET [Special Order Heater]
GECKO 4.5kw 240V 3″x15″ Flow Thru Heater
C2550-3602ET-G [Special Order Heater]
GECKO 5.5kw 240V 3″x15″ Flow Thru Heater
C2550-0601 Click for Details
GECKO 5.5kw 240V 2″x15″ M Class Flow Thru Heater
Replaces: C2550-0601ET, B24055LAS, B24055LASD, B24055U, 20-00250, 20-00251, 20-00249, & 20-00270
C2400-0601 Click For Details
GECKO 4.0kw 240V 2″x15″ M Class Flow Thru Heater
Replaces: WATKINS C2400-C3330-1A, WATKINS C2400-C2695-1, B24040LAS, 20-00294, NORDIC C2695-1, C2400-0601ET, 20-00271, 20-00280, 20-00281, 20-00292, 20-00296, & 20-00410
C2550-0800 Click For details
GECKO 5.5kw 240V 2″x15″ S Class Flow Thru Heater
Replaces: C2550-0800ET, B24055GM, 20-00272, & 20-00274
C2400-0800 Click for Details
GECKO 4.0kw 240V 2″x15″ S Class Flow Thru Heater
Replaces: C2400-0800ET, B24040GM, 20-00284, & 20-00285
C2550-0155 Click For Details
HERCULES 5.5kw 240V 2″x18″ Flow Thru Heater
Replaces: C2550-0157, C2550-0154, & 48-3300-10-154H; 48-3300-10-155H
C2550-0309 [Special Order Heater]
HYDRO QUIP 5.5kw 240V 2″x15″ Flow Thru Heater
Replaces: C2550-0309ET, 20-00287C, & B23025R1
C2550-0307 Click here for details
HYDRO QUIP 5.5kw 240V 2″x15″ Flow Thru Heater
Replaces: C2550-0307ET, 20-00227, 20-00328
C2450-0307 Click For Details
HYDRO QUIP 4.5kw 240V 2″x15″ Flow Thru Heater
Replaces: C2450-0307ET
C2400-0307 [Special Order Heater]
HYDRO QUIP 4.0kw 240V 2″x15″ Flow Thru Heater
Replaces: C2400-0307ET
C2550-0002 [Special Order Heater]
HYDRO QUIP 5.5kw 240V 2″x15″ Flow Thru Heater
Replaces: C2550-0002ET, 20-00224
C2400-0002 [Special Order Heater]
HYDRO QUIP 4.0kw 240V 2″x15″ Flow Thru Heater
Replaces: C2400-0002ET
C21100-3077 [Special Order Heater]
HYDRO QUIP 11kw 240V 3″x19.25″ Dual Element Flow Thru Heater
C1100-1200-1 Click for Details
HYDRO QUIP 1.0kw 120V 2″x10″ Flow Thru Heater
C1100-0012 [Special Order Heater]
JUMP KING 1.0kw 120V 1.5″x8.5″ Flow Thru Heater
Replaces: 48-3400-30-01-012
C2400-0001 [Special Order Heater]
4.0kw 240V 2″x12″ Flow Thru Heater
Replaces: 48-3600-10-001H
C2550-0736 Click for Details
LA – ADVANCED 5.5kw 240V 2″x15″ Flow Thru Heater
Replaces: B24055LA2, 48-3300-10-736H
C2550-0071 [Special Order Heater]
LA – ADVANCED 5.5kw 240V 2″x15″ Flow Thru Heater
Replaces: B24055LA, 48-3300-10-071H
C2550-0073 [Special Order Heater]
MADDOX ENT. 5.5kw 240V 2″x15″ Flow Thru Heater
Replaces: 20-00326, C2550-0073-S (Set), C2550-0072
C2400-0073 Click For Details
MADDOX ENT. 4.0kw 240V 2″x15″ Flow Thru Heater
Replaces: 20-00247, C2400-0073-S (Set)
C2400-C2550-2 [Special Order Heater]
NORDIC 4.0kw 240V 2″x15″ Flow Thru Heater
C2550-0313N Click for Details
NUWAVE/WEST COAST 5.5kw 240V 2″x15″ Flow Thru Heater
Replaces: 20-00348, B24055C1
C2400-0313N [Special Order Heater]
NUWAVE/WEST COAST 4.0kw 240V 2″x15″ Flow Thru Heater
C2550-0213N Click for details
NUWAVE/WEST COAST 5.5kw 240V 2″x19″ Flow Thru Heater
Replaces: C2550-0213, 20-00406, B24055C, 48-3300-10-013H
C2400-0213N [Special Order Heater]
NUWAVE/WEST COAST 4.0kw 240V 2″x19″ Flow Thru Heater
C2550-0256 Click for details
SBSG 5.5kw 240V 2″x15″ Flow Thru Heater LX20/25/30
Replaces: C2550-0256ET, 48-3300-10-256H
C2400-0256 [Special Order Heater]
SBSG 4.0kw 240V 2″x15″ Flow Thru Heater LX20/25/30
Replaces: C2400-0256ET
C2550-0056 Click for details
SUNDANCE/SBSG 5.5kw 240V 2″x15″ Flow Thru Heater AP1 & LX15
Replaces: C2550-0056ET, B24055Q(QC), 20-00227, C2550-0556 (SC), C2550-0556
C2400-0056 Click for details
SUNDANCE/SBSG 4.0kw 240V 2″x15″ Flow Thru Heater AP1 & LX15
Replaces: C2400-0056ET, B24040Q(QC), 20-00354, C2400-0556
C2550-1002 Click for details
SUNDANCE/SBSG 5.5kw 240V 2″x12″ Flow Thru Heater AP4 & LX10
Replaces: C2550-1002ET, 48-3300-10-002H / 48-3300-10-003H
C2400-1002 Click for details
SUNDANCE/SBSG 4.0kw 240V 2″x12″ Flow Thru Heater AP4 & LX10
Replaces: C2400-1002ET, 48-3600-10-002H
C2550-0120 Click for Details
SUNDANCE/SBSG 5.5kw 240V 2″x15″ Flow Thru Heater
Replaces: 48-3300-10-120H / 6500-211
C2550-0267ET Click for Details
SUNDANCE/SBSG 5.5kw 240V 2″x15″ Flow Thru Heater
Replaces: C2550-0267
C2400-0267ET [Special Order Heater]
SUNDANCE/SBSG 4.0kw 240V 2″x15″ Flow Thru Heater
Replaces: C2400-0267
C2550-0119 Click Here to View
SUNDANCE/MARQUIS 5.5kw 240V 2″x15″ L Shape Heater
Replaces: 48-3300-10-119H
C2550-0104 Click Here to View
SUNDANCE 5.5kw 240V 2″x12″ Flow Thru Heater
C2400-0104 [Special Order Heater]
SUNDANCE 4.0kw 240V 2″x12″ Flow Thru Heater


This post first appeared on Spa Parts Help, please read the originial post: here