Hydra-Cell® Diaphragm Pump Technology for Minimizing Shear Effects in EOR Polymer Solutions

Introduction

Diaphragm Pump TechnologyPolymer flooding is a mature technology and continues to be the dominant form of chemical enhanced oil recovery (EOR). However, many industry insiders know that the intended viscosity of a polymer solution and the actual viscosity injected in the reservoir tend to vary significantly. This is primarily due to shear effects (polymer degradation) in equipment and piping systems.

With the typical lifetime from reservoir screening to pilot EOR projects being two to four years, operators cannot afford operational inefficiencies and increased CAPEX / OPEX in their projects and must reliably inject what was designed. A main cost driver for larger-scale projects is the price of polymer, and degraded polymer affects overall recovery and reserves. Cost savings with low shearing pumps are crucial to the overall econom- ics of polymer EOR projects.

Experimental Setup

Wanner Engineering’s Hydra-Cell T100K triplex diaphragm pump was tested, with a patent-pending collec- tion system and method, to minimize shear effects and characterize viscoelastic response from a medium mo- lecular weight polymer solution (12 MDalton). Dr. Vladimir Alvarado and his team conducted the experiment at the University of Wyoming.

Experimental measurements included rheometer measurements, nuclear magnetic resonance (NMR) measurements, and dynamic light scattering (quality control checks).

  • Rheometer measurements included flow sweep, frequency sweep, and strain sweep measurements to collect dynamic viscosity and complex modulus rheology data.
  • NMR measurements included T2 distributions and diffusion coefficients.

These measurements ensured experimental quality and stability.

Summarized below are the parameters at which the T100K’s effect on polymer was tested. It should be noted that the T100K can achieve a maximum flow rate of 45 gpm at 3000 psi.

Table 1 | Experimental pressures, flow rates, and polymer viscosities tested (at 10 s-1)

Results and Discussion

On average, the Hydra-Cell T100K demonstrated a 1% to 5% degradation of polymer viscosity. Experimental results show a maximum percent difference between the storage tank and pump discharge solution viscosity was less than 5%, observed at 34 gallons per minute through the T100K. Results further demonstrate no con- sistent trend between the percent decrease in viscosity and either the discharge pressure or the pump flow rate.

The experimental system and piping did have a non-negligible impact on polymer solution viscosity reduction, suggesting that polymer degradation through the T100K is most likely even less than the measured 1% to 5% viscosity reduction.

Overall, Wanner Engineering’s Hydra-Cell T100K has demonstrated a marked improvement and decrease in polymer solution viscosity degradation over what is generally seen in oilfield projects (10% to 15%).

Run #1 | Viscosity reduction

Figure 1 – Run #1 sample data. This run shows a 1% to 5% viscosity reduction increasing with flowrate and independent of pressure. Subsequent runs showed similar results.

Conclusions

Diaphragm Pump Technology – The Wanner Engineering Hydra-Cell T100K is an excellent choice for polymer EOR applications. Operators will save money on polymer injection costs due to the reduction of polymer usage via less degradation in the Hydra-Cell pump. They also have the advantage of injecting polymer slugs that match design specifications without having to overdose their solutions, aiding in reduced OPEX and increased reserves.

Operators will see immediate cost savings in operational expenses compared to triplex plunger pump counter- parts. Unlike plunger pumps, the Hydra-Cell hydraulically actuated diaphragm pumps do not have packing or seals to repair and replace. The Hydra-Cell’s plungers do not contact the process liquid and require no external lubrication, ending the need for lubricating equipment installation and underground lubricant disposal tanks or pump lubricant drains. Additionally, the T Series can run dry without damage if the pump is accidentally starved. Over the course of three years, operators are expected to save more than $40,000 on pump maintenance alone versus a plunger pump.

The post Hydra-Cell® Diaphragm Pump Technology for Minimizing Shear Effects in EOR Polymer Solutions appeared first on Monitor Pumps.



This post first appeared on Monitor Pumps, please read the originial post: here

Share the post

Hydra-Cell® Diaphragm Pump Technology for Minimizing Shear Effects in EOR Polymer Solutions

×

Subscribe to Monitor Pumps

Get updates delivered right to your inbox!

Thank you for your subscription

×