Most Common Surgical Camera Repair Issues

The Surgical Camera also forms a part of endoscopy surgery therefore used with Rigid and Flexible Endoscopes as well. Different types, models, shapes, size, and style, depending on the function and intended area of use enable a surgeon to select the type of Camera and Endoscope. Once damaged, it can be expensive to repair a surgical camera and scopes.

Some common Surgical camera issues that require repair:

  1. Improper/ Wrong Sterilisation – If the surgical camera is not sterilised properly, image becomes blurry. Residue on other parts and joints may cause further damage. Surgical cameras could be sterilised either by chemical or steam sterilisation, depending on the instruction by manufacturer. If steam sterilisation has been used when chemical/ ETO sterilisation was required for the camera as per the manufacturer, there could be damage to cable, sleeve etc.
  2. Physical hit or drop – Camera and scopes should be gently handled at all times. Any rough or careless handling could result in dropping or hitting the camera against hard surface and can cause significant damage. Inside the camera head, there are electronics mounted to a tiny glass block. If any of these components get disturbed, it can cause image issues, a static image, or an unclear image. If dropped or damaged the camera head may produce anomalies in image formation and it needs repair or replacement.
  3. Cable damage /Cut/ Crack – The cable houses several fine and delicate wires. There could be burnt or cut fibre optics or damaged cable due to other mishandling of other instruments/equipment used with it. Improper sterilisation could cause the jackets on the cable to crack or break. Wear and tear of the cable is common.
  4. Connector pin damage – Connector pin could be damaged due improper insertion and can result in poor, inconsistent images.
  5. Strain relief damage – Frequent usage or rough handling could exert pressure on the strain relief between the cable and connector hence damaging the connection.
  6. Coupler damage – A coupler further connects the scope to the camera. Doctors frequently need to change scopes, depending upon the surgery while using the same camera (and the rest of the stack). Wear and tear is easily observed in the coupler. Coupler’s snap rings could fail or take on fluid. The coupler could also be dropped, damaging its components.

Reliable Surgical Camera Repair Services in India

Proper care and handling can extend the life of surgical cameras, but in some cases, you’ll need a reliable repair service. When it comes to customer service, technical service and all other kind of medical assistance with respect to repairs and servicing, PrimedeQ is the right place with the following types of surgical camera repairs and refurbishment:

  1. Cable assembly repair/replacement
  2. Connector pins repair/replacement
  3. Strain reliefs repair/replacement
  4. Coupler repair/replacement
  5. Camera prism blocks and optical focus replacement/ adjustments
  6. Face plate/Mounts replacement
  7. CCU repairs
  8. Camera head cable repair/replacement.

We handle all brands and models of Surgical Cameras owing to our Service team and Service Partners. Some of the leading players in the market with respect to surgical cameras include Karl Storz, Olympus, Stryker, Conmed, Smith & Nephew. We repair all kinds of Camera Heads including all challenging repairs (like Karl Storz H3Z, Storz H3Fa, Telecam, Tricam, and all others).

—————————————————————————————————————————

PrimedeQ is an e-Marketplace for buying, selling, renting, servicing and spares of medical equipment. We offer all types of used / refurbished medical equipment , including ENT equipment, Laparoscopic Equipment,  Lab equipment, X-Ray, TMT, ECG, anesthesia machine, ultrasound machines etc.  We offer microdebrider,  laparoscope , endoscope and ultrasound probe repair services etc.

Contact us on +91 8971223957/ 7019759765 or [email protected]

The post Most Common Surgical Camera Repair Issues appeared first on Primedeq-Blog.



This post first appeared on PrimedeQ, please read the originial post: here

Share the post

Most Common Surgical Camera Repair Issues

×

Subscribe to Primedeq

Get updates delivered right to your inbox!

Thank you for your subscription

×